Ketema . . .
   providing world-
   class engineered    solutions for
   aerospace systems
Senior Aerospace - Ketema
 

IN THIS SECTION


Fuel Management Systems

Signal Conditioners

Several models, using both analog and digital circuitry, are available to interface engine-mounted flowmeters to cockpit rate indicators and totalizers. PC600 and PC800 series units support legacy systems, while the PC910/PC920 systems are designed to upgrade existing systems, and to provide an accurate link to new Flight Management Systems.

Features:

  • Direct replacement for current legacy systems
  • Interfaces with newer flight management systems with current instrumentation
  • Established product history

Specifications:

The PC910 (single) / PC920 (dual) series of signal conditioners conform to the requirements of FAA document TSO-C44b.

blank blank
Flow Sensor input: Input full scale frequency range: 1600 Hz Max
Input:

Input Type: Balanced
Input Impedance: 20K ohms
Input Sensitivity: 7 millivolts RMS at frequencies < 100 Hz

Temperature: Temperature Sensor Type: RTD, Nickel 270 Alloy
Sensor Input: Temperature Sensor Resistance @ 25°C:1000 ohms +/- 1%
Temperature Coefficient: 6 ohms per °C
Temperature Range: -67°C to 158°F
(-55° to 70°C)
Totalizer Output: Output type: Solid-State switch to ground
Current sink: 400 mA maximum
Totalizer supply source: +28 vdc fuse protected
Pulse width: 50 ms
Rise/fall time: < 25/us
Output frequency: dependant on scaling, 10 Hz maximum
Accuracy: +/- 3% of indicated total with fuel at nominal density, variations in fuel density from nominal will affect accuracy
Indicator Rate Output: Accuracy: +/- 3% of full scale flow rate with fuel of nominal density
Fuel density variations from nominal will affect accuracy
Linearity: +/- 1% of full scale
Output Impedance: > 400K ohms
Auxiliary Analog Output: Type: Voltage output signal proportional to flow rate
Full Scale Voltage: 5.000 or 5.333 vdc
Slew rate: < 0.5 s from zero to full scale
Accuracy: +/- 2.0% of full scale
Repeatability: +/- 0.1% of full scale
Linearity: +/- 0.2% of full scale
Temperature Drift: +/- 0.01% of full scale per °F (+/- .02% of full scale per °C)
Output Impedance: < 1K ohms
Power Requirements: Voltage: +10 to 32 vdc
Current: Each channel 75mA typical 100mA maximum, excluding totalizer current
Temperature Range: -22° to +122°F
-30° to +50°C
Mating Connectors: J1 - MS3116F14-15S
J2 - MS116F14-15SX

790 Greenfield Drive
El Cajon, CA 92021

T: +1 619 588-3373
F: +1 619 588-3381

Email: Dick.Hoolihan@sfketema.com

Location Map


Signal Conditioners
Home | Space | Propulsion | Fasteners | Fuel Management Systems


Copyright 2007 Senior Aerospace - Ketema | All Rights Reserved
Legal Information | Environmental Policy | Privacy Statement | Website development by Digital Intellect