IN THIS SECTION
|
Fuel Management Systems
Indicator Conditioners
The PC900 series of Indicators/Conditioners incorporate digital circuitry to condition, temperature compensate, and accumulate the output from an engine-mounted turbine flowmeter. They provide a traditional analog display of fuel flowrate in user specified units. Additionally, an auxiliary analog output is available to provide a convenient interface to a Flight Management System.
Features:
- Interfaces with newer flight management systems
- Established product history
Specifications:
The PC900 series of indicator/conditioners conform to the requirements of FAA document TSO-C44a.
 |
 |
| Models: |
Meter movement with integrated signal conditioner (hub lighted)
Stepper motor with integrated signal conditioner (back lighted) |
| Construction: |
2 inch round analog face with center pointer (250 degree scale) |
| Power Requirements: |
19-32 volts DC 50 to 300 mA |
| Lighting: |
5 volt or 28 volt |
| Full-scale Reading: |
Standard: 300 to 7000 pounds per hour full scale
Custom: as specified by customer including logos and color |
| Inputs: |
All 300 series flowmeters with fuel temperature sensor
Remote input from a second indicator/ signal conditioner for dual engine totalizer function |
| Outputs: |
Totalizer 28 volt/50 mS pulse (suitable for driving electro-mechanical counter)
Auxiliary output (selectable)
0 to 1 mA DC analog proportional to flowrate
0 to 5 Volts DC analog proportional to flowrate
Remote totalizer for connection to a second indicator/conditioner for dual engine totalizer function |
Total Indicated
Flowrate Accuracy: |
+/- 3% of full scale |
| Auxiliary Output Accuracy: |
+/- 2% of full scale
+/- 0.5% of full scale linearity
+/- 0.1% of full scale repeatability |
| Temperature Environment: |
-30 to 50°C operating temperature |
| Connector: |
MS3112E14-15P |
| Mating Connector: |
MS3116F14-15S |
|
790 Greenfield Drive
El Cajon, CA 92021
T: +1 619 588-3373
F: +1 619 588-3381
Email: Dick.Hoolihan@sfketema.com
|